Error description
HWNPM2132W Performance data could not be collected for device xxxxxxxxxxxxxx (00000123456789A). The current samples are skipped. (HWNPM4305W No samples were received from the data collector in the expected time. The data might still arrive automatically after connection is recovered.) The performance monitoring for the storage system is running on the data collector based on the performance manager interval 15 minutes instead of 5 minutes. The SI Device server is pooling for data. So, the performance job is not synchronized in what should be the interval for PM defined for this storage system in repository versus the running PM job on DC. In the storage device input file: opt/IBM/TPC/device/log/xxxxxxxxxxxxxx/perf_monitor/xxxxxxxx/xxxx xxxxxxxxxx_input.txt .... #Thu Nov 26 01:27:23 EST 2020 ? Username=xxx Timeout=300 IntervalLength=900 The scheduled PM interval on the DC doesn't match the SI server polling interval for data collection running for that device.
Local fix
Contact IBM Support
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Storage Insights users collecting performance data * **************************************************************** * PROBLEM DESCRIPTION: * * Error encountered while collecting performance data: * * * * HWNPM2132W Performance data could not be collected for * * device * * xxxxxxxxxxxxxx (00000123456789A). The current samples are * * skipped. (HWNPM4305W No samples were received from the data * * collector in the expected time. The data might still arrive * * automatically after connection is recovered.) * * * * The performance monitoring for the storage system is running * * on * * the data collector based on the performance manager interval * * 15 * * minutes instead of 5 minutes. The SI device server is * * pooling * * for data. So, the performance job is not synchronized in * * what * * should be the interval for PM defined for this storage * * system in * * repository versus the running PM job on DC. * * * * The scheduled PM interval on the DC doesn't match the SI * * server * * polling interval for data collection running for that * * device. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The fix for this APAR is contained in the following release: IBM Storage Insights 4Q 2020 [ 5.4.1-IBM-SC ]
Temporary fix
Comments
APAR Information
APAR number
IT35474
Reported component name
STORAGE INSIGHT
Reported component ID
5608TPCSI
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-01-11
Closed date
2021-03-24
Last modified date
2021-03-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STORAGE INSIGHT
Fixed component ID
5608TPCSI
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSQRB8","label":"IBM Storage Insights"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"540","Line of Business":{"code":"LOB69","label":"Storage TPS"}}]
Document Information
Modified date:
12 January 2026