IBM Support

IT35370: ADDED HANDLING OF SPECIAL IMS IRM_TIMER VALUES 0 AND -1

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The IMS IRM_TIMER has special values which are not durations in
    milliseconds. Support for these values, 0 and -1, have been
    added with this APAR.
    
    Value 0:  Use default values. The default for all RESUME_TPIPE
    is two seconds. The default for all RESUME_TPIPE non-single ACK
    is .25 seconds. The value of the TIMEOUT parameter in the IMS
    Connect TCPIP configuration statement for all others.
    
    Value -1 (0xFF): Wait indefinitely. This setting is intended to
    support the auto option of the asynchronous output function
    

Local fix

Problem summary

  • Added handling of IMS IRM_TIMER values 0 and -1 for IMS Callout
    Handler.
    
    The IRM_TIMER has special values which are not durations in
    milliseconds.
    
    Adding the value 0 to use default values:
    1. The default for all RESUME_TPIPE is two seconds.
    2. The default for all RESUME_TPIPE non-single ACK is .25
    seconds.
    3. The value of the TIMEOUT parameter in the IMS Connect TCPIP
    configuration statement for all others.
    
    Adding the value -1 (0xFF) to wait indefinitely.
    

Problem conclusion

  • Fixed in 2018.4.1.16, 10.0.1.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT35370

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    18X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-01-14

  • Closed date

    2021-03-30

  • Last modified date

    2021-03-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R770 PSY

       UP

  • RA0X PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18X"}]