IBM Support

IT35073: ESCAPED DELIMITER AT THE VERY END OF A MESSAGE DOES NOT PARSE

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • When the last character of a message is an escaped delimiter
    
    character then the message will not parse and a CTDP3002E:
    
    exception will be seen.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users of IBM Integration Bus or App Connect Enterprise that use
    the DFDL parser.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    A <span style="background-color:rgb(255, 255, 255)">CTDP3002E
    message will be seen if the last character of a message is an
    escaped delimiter. Escaped delimiters earlier in the message are
    handled correctly, it is only when they are the last character
    in the message that this issue occurs.</span>
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT35073

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-11-26

  • Closed date

    2022-02-24

  • Last modified date

    2022-02-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]

Document Information

Modified date:
25 February 2022