Error description

  • Customer reported that every time they mouse hover and leave it
    there at the leftmost side of OIA causes the CPU spikes up in
    processes as indicated in the Windows Task Manager. This is
    where MA (SNA type connection notification) and the Session
    letter is displayed. Moving the mouse away the CPU goes back to
    zero. Affected version of PComm are v14.0.2, v14.0.1 and 13.0.2
    (32 bit).
    

Local fix

  • Move the mouse away from the OIA. PComm users need to be
    mindful not to leave the mouse pointer at the leftmost side of
    the OIA.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All IBM Personal Communications users                        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When mouse hover is on the OIA control information column,   *
    * it should show the corresponding tooltip and after few       *
    * seconds tooltip should disappear. In this case, tooltip did  *
    * not disappear as well as CPU spike was not reduced.          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Below are the steps to reproduce the problem:
    
    1. Launch the PCOMM 5250 session
    2. Move the mouse position to OIA control area
    3. Mouse hover on any one of information columns
    4. It will be display the corresponding the tooltip and check
    the CPU spike of PCSWS using task manager
    

Problem conclusion

  • PCSWS.EXE changes have been made to display tooltip only once
    even though the mouse hover is on the same column.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT34739

  • Reported component name

    PCOMM COMBO-J

  • Reported component ID

    5639I700J

  • Reported release

    E00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-30

  • Closed date

    2020-12-09

  • Last modified date

    2020-12-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • PCSWS
    

Fix information

  • Fixed component name

    PCOMM COMBO-ENG

  • Fixed component ID

    5639I7000

Applicable component levels

  • RD00 PSY

       UP

  • RE00 PSY

       UP

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E00"}]

Document Information