APAR status
Closed as program error.
Error description
After configuring the Hitachi Export Tool and adding a G1500, no performance data is collected by Spectrum Control. Exit code -29 indicates that an invalid interval was set. 1 minute and 5 minute intervals are the only supported intervals. performance monitoring job log... HWNPM2122W No valid performance data was provided by the monitored resource. No performance data records were inserted into the database. perf_monitor\20135\process_hitachi_vsp.log... INFO - Hitachi Performance Monitor sample interval set to: 15 ERROR - ERROR - Data collection error DEBUG - Traceback (most recent call last): File "hitachi_vsp.py", line 96, in main File "DataCollect.py", line 948, in collect SystemExit: 0 DEBUG - Writing status file... DEBUG - Exit code: -29
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Control & Storage Insights users monitoring * * Hitachi performance with incorrect interval * **************************************************************** * PROBLEM DESCRIPTION: * * After configuring the Hitachi Export Tool and adding a * * G1500, * * no performance data is collected. * * * * Exit code -29 indicates that an invalid interval was set. * * Only 1 minute and 5 minute intervals are supported * * intervals. * * The configuration of performance interval was incorrectly * * setup. * * Once reconfigured the performance monitoring works fine. * * * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following release: IBM Spectrum Control 5.4.2 [ 5.4.2-IBM-SC ] ( release target 1Q 2021 / February ) IBM Storage Insights 1Q21 [ 5.4.1-IBM-SI-Patch ] IBM Storage Insights 2Q21 [ 54X-IBM-SI ] http://www.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future releases do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Patch fixes are available for both: Spectrum Control / Storage Insights 5.4.0 Spectrum Control / Storage Insights 5.4.1
Comments
APAR Information
APAR number
IT34669
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-23
Closed date
2021-01-08
Last modified date
2021-05-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNE44","label":"Tivoli Storage Productivity Center"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"540"}]
Document Information
Modified date:
25 June 2022