IT33891: DS8000 PROBES FAIL WHEN MICROCODE VERSION INFORMATION IS BLANK

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Storage Insights probes for DS8000 devices collect microcode
    information from the DS8000 device. When the DS8000 device
    provides an empty microcode version, the probe fails and logs
    the following:
    
    Probe failure messaging is as follows:
    Error
    HWNEP0129E The operation failed because the device returned
    unexpected values.
    Error HWNEP0134E Following exception
    occurred: com.ibm.tpc.ep.base.EPHdlrRunException: Retrieved
    empty MicrocodeLevel for lpars.
    Error HWNEP0135E External
    process failed with error code -101.
    Error HWN021503E The
    action cannot be completed
    Information HWN021709I Collection
    for storage system DS8000-2107-75XXXXX-IBM completed.
    Error
    BTADS0102E The probe with the run ID 68332 completed with
    errors.
    
    The LPARs not reporting microcode numbers to Storage
    Insights are:
     [EP-SubJob: DS8000-2107-xxxxxxx-IBM-8124]
    [EP_DS_CLI_Probe.getStorageServers] [ERROR] Retrieved empty
    MicrocodeLevel for lpar: SF75KXXXXXXXX
     [EP-SubJob:
    DS8000-2107-xxxxxxx-IBM-8124]
    [EP_DS_CLI_Probe.getStorageServers] [ERROR] Retrieved empty
    MicrocodeLevel for lpar: SF75KXXXXXXXX
    
    
    This happens when the
    DS8K has a CEC that is down. A CEC being down should not cause
    a probe to fail, nor should missing microcode level
    information. DS8K support and development are aware of the
    issue; possible change to DS8K behavior in this situation is
    also being analyzed. This APAR addresses the IBM Storage
    Insights behavior in response to this DS8K condition.
    
    
    ________
    ____________________________________________
    
    The defect is
    against component: Storage Insights
    Server/Manager
    build/release (TPC): 5.3.7
    Problem as described by customer:
    Degraded monitoring status for DS8K systems;
    Initial customer
    impact (low/med/high): low
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Control & Storage Insights users monitoring     *
    * DS8000 while the device has a CEC that is down               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Storage Insights probes of a DS8000 device collects          *
    * microcode                                                    *
    * information from the DS8000 device. When the DS8000 device   *
    * provides an empty microcode version, the probe fails and     *
    * logs                                                         *
    * the following:                                               *
    *                                                              *
    * Probe failure messaging is as follows:                       *
    *                                                              *
    * Error HWNEP0129E The operation failed because the device     *
    * returned unexpected values.                                  *
    *                                                              *
    * Error HWNEP0134E Following exception occurred:               *
    * com.ibm.tpc.ep.base.EPHdlrRunException:                      *
    * Retrieved empty MicrocodeLevel for lpars.                    *
    *                                                              *
    * This happens when the DS8K has a CEC that is down. A CEC     *
    * being down should not cause a probe to fail, nor should      *
    * missing                                                      *
    * microcode level information.  DS8K support and development   *
    * are                                                          *
    * aware of the issue; possible change to DS8K behavior in this *
    *                                                              *
    * situation is also being analyzed.                            *
    *                                                              *
    * This APAR addresses the IBM Storage Insights behavior in     *
    * response to this DS8K condition.                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Storage Insights 4Q20   [ 5.4.1-IBM-SC ]
    IBM Spectrum Control 5.4.1   [ 5.4.1-IBM-SC ]
    
    ( release target 4Q 2020 / November )
    
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT33891

  • Reported component name

    STORAGE INSIGHT

  • Reported component ID

    5608TPCSI

  • Reported release

    537

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-08-13

  • Closed date

    2020-10-08

  • Last modified date

    2020-10-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STORAGE INSIGHT

  • Fixed component ID

    5608TPCSI

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSQRB8","label":"IBM Storage Insights"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"537","Line of Business":{"code":"LOB69","label":"Storage TPS"}}]

Document Information

Modified date:
12 January 2026