Fixes are available
APAR status
Closed as program error.
Error description
If an API contains a GatewayScript policy that executes an apim.setvariable function call that manipulates message.body, the Content-Type header is set to unknown. This might cause issues with invoke policy target servers, or the API client.
Local fix
To resolve this problem, you must immediately follow the apim.setvariable function call with an apim.output function call that specifies the content type of the payload that was written to message.body by apim.setvariable.
Problem summary
Do not overwrite the content-type header when setting the message.body
Problem conclusion
The fix is in 2018.4.1.13 and 10.0.1.1
Temporary fix
Comments
APAR Information
APAR number
IT33845
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
18X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-08-07
Closed date
2020-11-06
Last modified date
2020-11-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R18X PSY
UP
RA0X PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18X"}]
Document Information
Modified date: