Error description

  • The IIB v10 and ACE v11 administration web user interfaces send
    the X-Frame-Origin header with a value of "SAMEORIGIN" with
    every request to provide protection against click jacking
    attacks.
    
    This header prevents the web user interface from
    being embedded in another website. While this is generally the
    preferred default for most users, some users wish to embed the
    web user interface within their own administrative dashboards
    which requires that the X-Frame-Options header not be
    set.
    
    This APAR introduces new configuration options that allow
    the X-Frame-Options header value to be changed or to prevent
    the header from being sent at all.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users IBM Integration Bus v10 and IBM App Connect Enterprise
    v11 wishing to embed web user interface in another webpage.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    The IIB v10 and ACE v11 administration web user interfaces send
    the X-Frame-Origin header with a value of "SAMEORIGIN" with
    every request to provide protection against click jacking
    attacks.
    
    This header prevents the web user interface from being embedded
    in another website. While this is generally the preferred
    default for most users, some users wish to embed the web user
    interface within their own administrative dashboards which
    requires that the X-Frame-Options header not be set.
    

Problem conclusion

  • A new setting has been added to v10 and v11 called
    "antiClickJackingOption".
    
    At v10 this setting is on the webadmin server component and can
    take one of the following values:
    
    * "SAMEORIGIN" - sets the X-Frame-Origin header to "SAMEORIGIN"
    * "DENY" - sets the X-Frame-Origin header to "DENY"
    * "disabled" - disables sending the X-Frame-Origin header. This
    disables anti clickjacking protection.
    
    This value can be changed by running mqsichangeproperties BROKER
    -b webadmin -o server -n antiClickJackingOption -v <VALUE>
    
    At v11 this setting is the RestAdminListener section of the
    node.conf.yaml or server.conf.yaml and can take one of the
    following values:
    
    * "SAMEORIGIN" - sets the X-Frame-Origin header to "SAMEORIGIN"
    * "DENY" - sets the X-Frame-Origin header to "DENY"
    * "" (the empty string) - disables sending the X-Frame-Origin
    header. This disables anti clickjacking protection.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.22
    v11.0      11.0.0.10
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT33780

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-08-04

  • Closed date

    2020-08-25

  • Last modified date

    2020-08-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
26 August 2020