Error description
KnowledgeCenter page bj58270_.html incorrectly says 'maximumRateMsgsPerSec' value is divided equally among all threads that are running in the message flow. --- The maximum message rate value is divided equally among all threads that are running in the message flow irrespective of the number of input nodes within the flow to achieve the configured maximumRateMsgsPerSec. ---
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM AppConnect Enterprise V11.0 and IBM Integration Bus V10.0 using the maximumRateMsgsPerSec property. Platforms affected: z/OS, MultiPlatform **************************************************************** PROBLEM DESCRIPTION: KnowledgeCenter page bj58270_.html incorrectly says 'maximumRateMsgsPerSec' value is divided equally among all threads that are running in the message flow.
Problem conclusion
The following paragraph in product Knowledge Center page bj58270_ will be updated : From : "The system administrator is able to restrict the rate that an individual message flow can run at by setting the maximum rate property. The maximum rate is specified as the total number of input messages processed every second. The maximum rate value is divided equally among all threads that are running in the message flow irrespective of the number of input nodes within the flow." To : "The system administrator is able to restrict the rate that an individual message flow can run at by setting the maximum rate property. The maximum rate is specified as the total number of input messages processed every second by all the threads that are running in the message flow." Following example will also be removed from the documentation as it incorrectly describes the product functionality. -------------<p>The following three examples assume the maximum rate is set to 50, and helps to highlight some of the variations that can occur from basic to more complex scenarios:</p><ul><li>A message flow has one input node with no additional instances:<ul><li>Only a single thread in operation.</li><li>The full maximum rate allocation of 50 messages every second is applied to that one thread.</li></ul></li><li>A message flow has one input node with one additional instance:<ul><li>Two threads in operation. One for the node and one for the additional instance.</li><li>The maximum rate is split equally across the two threads. Each thread has a maximum rate allocation of 25 messages every second.</li></ul></li><li>A message flow has three input nodes with four additional instances that are specified on the first node and three additional instances that are specified on the second node:<ul><li>10 threads in operation. Three input node threads, four additional instance threads for the first node, and three additional instance threads for the second node.</li><li>The maximum rate is split equally across the 10 threads. Each thread has a maximum rate allocation of five messages every second.</li></ul></li></ul>-----------------
Temporary fix
Comments
APAR Information
APAR number
IT33752
Reported component name
INTEGRATION BUS
Reported component ID
5724J0540
Reported release
A00
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-07-31
Closed date
2021-01-14
Last modified date
2021-01-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]
Document Information
Modified date:
15 January 2021