Error description

  • If the Integration Server is attempted to stop then the
    monitoring events associated with the currently processing input
    messages may not get published. There won't be any error logged
    in the broker syslog file but the Integration Server service
    trace shows the following entry in it.
    
    ImbPublicationHelper::publishMessage , 'We have been stopped!
    dont attempt to publish'
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM AppConnect Enterprise V11.0 and IBM Integration
    Bus V10.0 using the monitoring events.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    When attempted to stop the Integration Server, its seen that the
    monitoring events generated by message flows, before the
    integration server shuts down, are not published . There won't
    be any error logged in the broker syslog file but the
    Integration Server service trace shows the following entry in
    it.
    
    ImbPublicationHelper::publishMessage , 'We have been stopped!
    dont attempt to publish'
    

Problem conclusion

  • The product now correctly publishes all the generated monitoring
    events after receiving a 'stop' command on the integration
    server.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.23
    v11.0      11.0.0.11
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT33637

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-07-22

  • Closed date

    2020-12-15

  • Last modified date

    2020-12-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]

Document Information

Modified date:
15 December 2020