APAR status
Closed as program error.
Error description
The Client Acceptor may allocate a random port even though the port values are explicitly specified in the client options via HTTPPORT and WEBPORTS options. It can happen if the specified port numbers are already in use. HTTP and TCP ports that dsmcad allocates can be seen in the dsmwebcl.log, for example: 04/20/2020 00:59:54 (dsmcad) Client Acceptor - Built Feb 4 2020 16:34:36 04/20/2020 00:59:54 (dsmcad) Version 8, Release 1, Level 9.1 04/20/2020 00:59:54 (dsmcad) ANS3000I TCP/IP communications available on port 1587. 04/20/2020 00:59:54 (dsmcad) Dsmcad is working in Webclient Schedule mode. 04/20/2020 00:59:54 (dsmcad) ANS3000I HTTP communications available on port 1581. Initial Impact: Medium IBM Spectrum Protect versions affected: Client 7.1.x and 8.1.x on all supported platforms Keywords: TSM TS003492352 HTTPPORT WEBPORT dsmcad CAD client acceptor
Local fix
Specify free ports when defining values for the HTTPPORT and WEBPORTS in dsm.opt/dsm.sys.
Problem summary
**************************************************************** * USERS AFFECTED: * * Backup-archive clients versions 7.1.8 and 8.1.x for all * * platforms * **************************************************************** * PROBLEM DESCRIPTION: * * See "Error Description" * **************************************************************** * RECOMMENDATION: * * Apply fixing level when available. This problem is currently * * projected to be fixed in level 8.1.12. * * Note that this is subject to change at the discretion of * * IBM. * **************************************************************** *
Problem conclusion
The backup-archive client allocates now only un-usable ports. For default ports the random ports could be allocated.
Temporary fix
Comments
APAR Information
APAR number
IT33111
Reported component name
TSM CLIENT
Reported component ID
5698ISMCL
Reported release
81W
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-06-08
Closed date
2020-11-30
Last modified date
2020-11-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CAD
Fix information
Fixed component name
TSM CLIENT
Fixed component ID
5698ISMCL
Applicable component levels
[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"81W"}]