IBM Support

IT32319: REPLY MESSAGES OF AN AGGREGATION MAY INCORRECTLY GO TO SYSTEM.BROKER.AGGR.UNKNOWN QUEUE

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • If SYSTEM.BROKER.AGGR.TIMEOUT queue has any message then reply
    messages of an aggregation can incorrectly get moved to
    SYSTEM.BROKER.AGGR.UNKNOWN queue. So even if all the reply
    messages arrived, the AggregateReply node completes the
    aggregation only after the timeout/unknown timeout value
    expires.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM AppConnect Enterprise V11.0 and IBM Integration
    Bus V10.0 using the AggregateReply Node.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    If SYSTEM.BROKER.AGGR.TIMEOUT queue has a message then reply
    messages of an aggregation may incorrectly get moved to
    SYSTEM.BROKER.AGGR.UNKNOWN queue if the aggregation fan-in
    message flow is configured with additional instances. Once a
    reply message is moved to SYSTEM.BROKER.AGGR.UNKNOWN queue, even
    if all the reply messages arrives, the AggregateReply node
    completes the aggregation only after the timeout/unknown timeout
    value configured in the node expires.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT32319

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-03-26

  • Closed date

    2020-05-26

  • Last modified date

    2020-05-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: