Error description

  • Connect and read timeout options like
    mail.imap.connectiontimeout and mail.imap.timeout are required
    for EmailInput node to avoid indefinite socket wait calls that
    can cause a hang in the thread .
    
    Also a user may want release the IIB cached connections of
    EmailInput node after certain period of inactivity so that a
    fresh connection is made.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All User of App Connect Enterprise V11 and IBM Integration bus
    V10 using the EmailInput node.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    The EmailInput node may become unresponsive (hang) when there
    are delays (indefinite wait) in the underlying socket
    communication to the email server.
    

Problem conclusion

  • The EmailServer policy(and the EmailServer configurable service
    in V10) has been extended with 3 new properties to specify the
    timeout value to the underlying socket connections. The 3 new
    properties are
    
    1. emailConnectionTimeout : EmailInput node's underlying socket
    connection timeout value in seconds. Default is infinite
    timeout.
    
    2. emailReadTimeout : EmailInput node's underlying socket read
    timeout value in seconds. Default is infinite timeout.
    
    3. emailConnectionIdleTimeout  : Idle connection(ie. connection
    with no mails received) timeout in seconds. Default is infinite.
    The connection will be closed if idle timeout exceeds for a new
    connection to open.
    
    In a reported customer case, the values are set to 5,5 and 300
    respectively to resolve a hang issue with EmailInput node.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.23
    v11.0      11.0.0.11
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT31968

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-03-13

  • Closed date

    2021-01-18

  • Last modified date

    2021-01-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Line of Business":{"code":"LOB36","label":"IBM Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]

Document Information

Modified date:
19 January 2021