Fixes are available
APAR status
Closed as new function.
Error description
IBM Personal Communications 32-bit needs to support the %SNAGROUP% environment variable in the LUNAME keyword of the RUI section of the .WS session profile.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All IBM Personal Communications SNA users * **************************************************************** * PROBLEM DESCRIPTION: * * Unable to set the environment variable for SNA Group LUName * **************************************************************** * RECOMMENDATION: * **************************************************************** PCOMM does not support the LUName parameter as an environment variable. Below are the steps to recreate the issue, 1. Create Environment variable "SNAGROUP" under System variable and set its value to LUPOOL (SNAGROUP=LUPOOL where LUPOOL is the pool name on this host) 2. Create a new PCOMM SNA session and save the same 3. Add the below section in the saved .WS file [RUI] LUName=%SNAGROUP% 4. Launch the above PCOMM session. 5. PCOMM session will not connect to the LUName of LUPOOL
Problem conclusion
PCSRUINW.DLL has been changed to add the code to support the environment variable for SNA LUName
Temporary fix
Comments
APAR Information
APAR number
IT30552
Reported component name
PCOMM COMBO-ENG
Reported component ID
5639I7000
Reported release
C00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-10-09
Closed date
2021-03-26
Last modified date
2021-03-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSRUINW
Fix information
Fixed component name
PCOMM COMBO-ENG
Fixed component ID
5639I7000
Applicable component levels
RC00 PSY
UP
RD00 PSY
UP
RE00 PSY
UP