  • Closed as program error.

Error description

  • The CDInput node fails to process the file, when the
    destination file path is an absolute path set in userfile.cfg.
    
    
    The user may see the following error:
    
    BIP7967I: The file ''/EAIFW-TEST/ConnectDirectIn/absolute.dat''
    is not within the directory ''/transfer/cd/app2eai'' specified
    as the cdPathToInputDir in the configurable service. IBM
    Sterling Connect:Direct transfer is ignored for the file.
    
    Additional Symptom(s) Search Keyword(s):CDINPUT, Absolute path,
    BIP7967I
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of  IBM Integration Bus V10 and App Connect Enterprise
    v11 using the CDInput Node.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    The CDInput node fails to process the file, when the destination
    file path is an absolute path and the download_dir property is
    configured in userfile.cfg.
    
    
    The user may see the following error:
    
    BIP7967I: The file ''/EAIFW-TEST/ConnectDirectIn/absolute.dat''
    is not within the directory ''/transfer/cd/app2eai'' specified
    as the cdPathToInputDir in the configurable service. IBM
    Sterling Connect:Direct transfer is ignored for the file.
    
    Additional Symptom(s) Search Keyword(s):CDINPUT, Absolute path,
    BIP7967I
    

Problem conclusion

  • Now the CDInput node successfully process the file, when the
    destination file path has and absolute path set and download_dir
    is configured in userfile.cfg file.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.21
    v11.0      11.0.0.9
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT30031

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-08-19

  • Closed date

    2020-06-03

  • Last modified date

    2020-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

  • RA00 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
12 June 2020