APAR status
Closed as program error.
Error description
When a flow with collector node where Collection Expiry is not set, or set to less than an input terminal timeout is deployed, BIP4715E error message will be reported in syslog. This should be reported as a warning and not an error message. Here is the description of BIP4715 message -------------------- The timeout value for terminal ''DataIn'' is greater than or equal to the collection expiry value. The timeout property for terminal ''DataIn'' has a value of ''60'', which is greater than or equal to the value of the collection expiry property (''0''). This means that collection expiry will always occur before the terminal has timed out. Reduce or remove the terminal timeout or extend the collection expiry. --------------------
Local fix
n/a
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus V10 and IBM App Connect Enterprise V11 using the Collector node Platforms affected: z/OS, MultiPlatform **************************************************************** PROBLEM DESCRIPTION: When a flow with collector node where Collection Expiry is not set, or set to less than an input terminal timeout is deployed, BIP4715E error message will be reported in syslog. Here is the description of BIP4715 message -------------------- The timeout value for terminal ''DataIn'' is greater than or equal to the collection expiry value. The timeout property for terminal ''DataIn'' has a value of ''60'', which is greater than or equal to the value of the collection expiry property (''0''). This means that collection expiry will always occur before the terminal has timed out. Reduce or remove the terminal timeout or extend the collection expiry. -------------------- <span style="background-color:rgb(255, 255, 255)">This should </span><span style="background-color:rgb(255, 255, 255)">be reported as a warning and not an error message. </span>
Problem conclusion
<span style="background-color:rgb(255, 255, 255)">BIP4715 </span> is changed to a warning message. Also it will not be reported when the collection expiry is not set. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.18 v11.0 11.0.0.7 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT29591
Reported component name
INTEGRATION BUS
Reported component ID
5724J0540
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-07-04
Closed date
2019-12-23
Last modified date
2019-12-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0540
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
23 December 2019