APAR status
Closed as program error.
Error description
XIPT003I - Error is connection refuse fdbk=111 tcp connects fails. All subsequent retries tried to connect to the primary address and failed with XIPT003I
Local fix
No Workaround
Problem summary
Users Affected: Sterling Connect:Direct for UNIX 4.2.0 Sterling Connect:Direct for UNIX 4.3.0 Problem Description: CD Unix will only traverse the alt.comm.outbound list once. After that, it only retries using the comm.info. Platforms Affected: All
Problem conclusion
Resolution Summary: Fixed code so that CD Unix will traverse the alt.comm.outbound list on each session retry until a good connection is made. Delivered In: Sterling Connect:Direct for UNIX 4.2.0.4.iFix080 Sterling Connect:Direct for UNIX 4.3.0.0.iFix005
Temporary fix
NA
Comments
APAR Information
APAR number
IT26811
Reported component name
STR CD FOR UNIX
Reported component ID
5725C9907
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-10-30
Closed date
2018-11-01
Last modified date
2018-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
NA
Fix information
Fixed component name
STR CD FOR UNIX
Fixed component ID
5725C9907
Applicable component levels