IBM Support

IT26475: SVC TIMEZONE CAUSES PERFORMANCE MONITORING DATA COLLECTION FAILURE - HWNPM4303E

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Performance monitoring began failing for the SVC after upgrading
    it to 7.8.1 due to an unrecognized format.  In the following
    clock example, the "-05" value for the America/Bogota (GMT -5)
    time zone was not recognized.  A non-numeric format for the time
    zone was expected.
    
    "Tue Sep 25 04:10:24 -05 2018". (method: svqueryclock)
    
    Error from the probe log:
    HWNPM2132W Performance data could not be collected for device
    SVC_device (WWN). The current samples are skipped. (HWNPM4303E
    An agent API call (svqueryclock) failed while attempting to
    retrieve performance data for the device.)
    
    tracePerf_SVC_device.log:
    StatsCollectorSvcNi             queryTimeZoneInfo
    ENTRY
    StatsCollectorSvcNi             queryTimeZoneInfo
    EXIT        return value = America/Bogota
    
    EPLauncherPm$PdcThread          run
    DEBUG_MIN   Exception occurred during statistics collection
      com.ibm.tpc.perf.pdc.PdcAgentException: The SVC clock setting
    is in an unrecognized format: "Tue Sep 25 04:10:24 -05 2018".
    (method: svqueryclock)
    at
    com.ibm.tpc.perf.pdc.StatsCollectorSvcNi.queryDateTimeInfo(Stats
    CollectorSvcNi.java:2148)
    at
    com.ibm.tpc.perf.pdc.StatsCollectorSvcNi.collectData(StatsCollec
    torSvcNi.java:701)
    at
    com.ibm.tpc.ep.base.EPLauncherPm$PdcThread.run(EPLauncherPm.java
    :702)
    

Local fix

  • Setting the SVC time zone to an alternate GMT -5 timezone, such
    as America/Chicago (73) allows data collection to continue until
    a fix can be applied.
    settimezone -timezone 73
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Control users monitoring SVC with unique        *
    * timezone                                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Spectrum Control performance monitoring of an SVC            *
    * began failing after upgrading the SVC to firmware 7.8.1      *
    * due to an unrecognized timezone format.                      *
    *                                                              *
    * Example:                                                     *
    * The following clock timezone "-05" value for                 *
    * America/Bogota (GMT -5) time zone was not recognized.        *
    * A non-numeric format for the time zone was expected.         *
    *                                                              *
    * This fix applies beyond this example, and corrects for any   *
    * numeric format, and should fix SVC and Storwize devices.     *
    *                                                              *
    *                                                              *
    * This problem exhibited as an error in the probe log:         *
    *                                                              *
    * HWNPM2132W                                                   *
    * Performance data could not be collected for device           *
    * SVC_device (WWN). The current samples are skipped.           *
    *                                                              *
    * HWNPM4303E                                                   *
    * An agent API call (svqueryclock) failed while attempting to  *
    * retrieve performance data for the device.)                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available                         *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Spectrum Control 5.3.1  |  5.3.1-IBM-SC
    
    ( release target Nov 2018 )
    
    http://www.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT26475

  • Reported component name

    TPC ADVANCED

  • Reported component ID

    5608TPCA0

  • Reported release

    52H

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-10-01

  • Closed date

    2018-10-10

  • Last modified date

    2018-10-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC ADVANCED

  • Fixed component ID

    5608TPCA0

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSC6VJ","label":"IBM Spectrum Control Advanced Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52H"}]