IBM Support

IT26288: RETRIEVING MPIO CONFIGURATION BY USING MPCLAIM COMMAND WITH -V OPTION CAUSES "ACCESS DENIED" ERROR

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Vendor Solution.

Error description

  • See this Microsoft support notification:
    https://support.microsoft.com/en-gb/help/3161579
    
    When the Encrypting File System (EFS) feature is disabled in
    Windows 2012 R2, such as by Group Policy, retrieving the MPIO
    configuration by using the mpclaim command together with the -v
    option causes an "Access Denied" error and doesn?t show the
    configuration.
    Note MPIO represents Microsoft Multipath I/O.
    
    The problem could be fixed by installing June 2016 update rollup
    for Windows RT 8.1, Windows 8.1, and Windows Server 2012 R2.
    However, after installing this update, mpclaim -v config.txt
    will continue to try to write to an encrypted file and won't
    work correctly when EFS is disabled.
    
    Therefore, besides to install the update mentioned above,
    Spectrum Control should change the SRA code to use -n flag for
    all mpclaim commands to avoid this problem totally.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • APAR opened in hopes of using an additional switch on the
    mplcaim command, but determined that tool does not operate as
    expected.
    

APAR Information

  • APAR number

    IT26288

  • Reported component name

    TPC

  • Reported component ID

    5608TPC00

  • Reported release

    528

  • Status

    CLOSED ISV

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-09-24

  • Closed date

    2019-02-13

  • Last modified date

    2019-02-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNE44","label":"Tivoli Storage Productivity Center"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"528"}]

Document Information

Modified date:
24 June 2022