Fixes are available
Db2 Version 11.1 Mod4 Fix Pack4 iFix001 for Linux, UNIX, and Windows
Db2 Version 11.1 Mod 4 Fix Pack 4 for Linux, UNIX, and Windows
Db2 Version 11.1 Mod 4 Fix Pack 6 for Linux, UNIX, and Windows
Db2 Version 11.1 Mod 4 Fix Pack 5 for Linux, UNIX, and Windows
Db2 Version 11.1 Mod 4 Fix Pack 7 for Linux, UNIX, and Windows
APAR status
Closed as program error.
Error description
PADiagLogColl::parseFilterParms shows up in db2diag.log with message "START TIMESTAMP and END TIMESTAMP" as following sample shows when application invoke PD_GET_DIAG_HIST() table function with invalid parameters where starttime > endtime, but no error return to the application. 2018-03-30-17.51.04.291464+540 E559724A1376 LEVEL: Error PID : 12345678 TID : 1234 PROC : db2sysc 0 INSTANCE: db2inst1 NODE : 000 DB : SAMPLE APPHDL : 0-32 APPID: *LOCAL.DB2.180330085039 AUTHID : XXXXX HOSTNAME: <host> EDUID : 3343 EDUNAME: db2agent (SAMPLE) 0 FUNCTION: DB2 UDB, RAS/PD component, PADiagLogColl::parseFilterParms, probe:20 MESSAGE : ECF=0x9000000C=-1879048180=ECF_INVALID_PARAMETER Invalid parameter DATA #1 : String, 42 bytes START TIMESTAMP greater than END TIMESTAMP DATA #2 : SQLCA, PD_DB2_TYPE_SQLCA, 136 bytes 0x0000000110FDCEC0 : 0000 0000 0000 0000 0000 0000 FFFF F810 ................ 0x0000000110FDCED0 : 0021 5354 4152 5420 5449 4D45 5354 414D .!START TIMESTAM 0x0000000110FDCEE0 : 5020 616E 6420 454E 4420 5449 4D45 5354 P and END TIMEST 0x0000000110FDCEF0 : 414D 5000 0000 0000 0000 0000 0000 0000 AMP............. 0x0000000110FDCF00 : 0000 0000 0000 0000 0000 0000 0000 0000 ................ 0x0000000110FDCF10 : 0000 0000 0000 0000 0000 0000 0000 0000 ................ 0x0000000110FDCF20 : 0000 0000 0000 0000 0000 0000 0000 0000 ................ 0x0000000110FDCF30 : 0000 0000 0000 0000 0000 0000 0000 0000 ................ 0x0000000110FDCF40 : 0000 0000 0000 0000 ........ 2018-03-30-17.51.04.292095+540 I561101A626 LEVEL: Warning PID : 12345678 TID : 1234 PROC : db2sysc 0 INSTANCE: DB2 NODE : 000 DB : SAMPLE APPHDL : 0-32 APPID: *LOCAL.DB2.180330085039 AUTHID : XXXX HOSTNAME: <host> EDUID : 3343 EDUNAME: db2agent (SAMPLE) 0 FUNCTION: DB2 UDB, WLM, sqlrwGetPDDiagHist_v10fp3, probe:200 MESSAGE : ECF=0x9000000C=-1879048180=ECF_INVALID_PARAMETER Invalid parameter DATA #1 : String, 75 bytes Error initializing the diag log collector. Not able to access the diag log. Local bypass: Make sure starttime is less than endtime when invoke PD_GET_DIAG_HIST()
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Db2 11.1 Mod 4 Fixpack 4 or higher * ****************************************************************
Problem conclusion
First fixed in Db2 11.1 Mod 4 Fixpack 4
Temporary fix
Comments
APAR Information
APAR number
IT25927
Reported component name
DB2 FOR LUW
Reported component ID
DB2FORLUW
Reported release
B10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-09
Closed date
2018-11-27
Last modified date
2022-03-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DB2 FOR LUW
Fixed component ID
DB2FORLUW
Applicable component levels
RB10 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSEPGG","label":"DB2 for Linux- UNIX and Windows"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: