APAR status
Closed as program error.
Error description
If the encrypted filesystem is full, the appliance might partially reset, but the WebGUI will not start, so the license cannot be accepted.
Local fix
Problem summary
Administrator's password might change to the default value, when the encrypted file system is full.
Problem conclusion
Fix is available in 7.1.0.23, 7.2.0.21, 7.5.0.16, 7.5.1.15, 7.5.2.15, 7.6.0.8 and 7.7.1.1 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT25469
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-06-22
Closed date
2018-07-17
Last modified date
2021-10-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"750"}]
Document Information
Modified date:
27 October 2021