IBM Support

IT24591: FDC with PROBE ID XY596010 does not report the associated operating system error code

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • When a Failure Data Capture (FDC) record with Prode ID XY596010
    is generated, the associated information does not contain the
    return code from the underlaying operating system call:
    
    MQM Function Stack
    zmuThreadMain
    zruResourceMonitor
    zruPublishSystemStats
    xcsQueryUsage
    xruQueryDiskUsageOS
    xcsFileSystemUsage
    xcsFFST
    
    | License Type      :- Production
                                                |
    | Probe Id          :- XY596010
                                                  |
    | Application Name  :- MQM
                                                       |
    | Component         :- xcsFileSystemUsage
                                        |
    | SCCS Info         :-
    /build/slot1/p900_P/src/lib/cs/unix/amqxnflx.c,        |
    | Major Errorcode   :- xecF_E_UNEXPECTED_SYSTEM_RC
                               |
    | Minor Errorcode   :- OK
                                                        |
    | Probe Type        :- MSGAMQ6119
                                                |
    | Probe Severity    :- 2
                                                         |
    | Probe Description :- AMQ6119: An internal IBM MQ error has
    occurred ()      |
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users of IBM MQ on Linux platforms.
    
    
    Platforms affected:
    Linux on x86-64, Linux on zSeries, Linux on x86, Linux on S390,
    Linux on Power
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    An omission in the error reporting logic meant that the relevant
    operating system return code was not inserted into the expected
    field within the FDC record.
    

Problem conclusion

  • The error reporting logic has been modified so that the error
    code reported from the operating system call will be written to
    the FDC record with probe ID XY596010 as arithmetic insert 1.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v9.0 LTS   9.0.0.5
    v9.1 CD    9.1.1
    v9.1 LTS   9.1.0.1
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT24591

  • Reported component name

    IBM MQ BASE M/P

  • Reported component ID

    5724H7261

  • Reported release

    902

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-04-01

  • Closed date

    2018-06-15

  • Last modified date

    2018-07-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IBM MQ BASE M/P

  • Fixed component ID

    5724H7261

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"902","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date: