APAR status
Closed as program error.
Error description
Any exception, which makes the resequence node to restore its previous state, can cause further messages of same group stuck in EVENTS queue.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All Users of IBM integration Bus V9.0 and V10.0 using Resequence node. Platforms affected: z/OS, MultiPlatform **************************************************************** PROBLEM DESCRIPTION: Exceptions which trigger the Resequence node to restore its previous state, can cause further messages of same group stuck in its internal queues. For example, a BIP2136E error when serializing an incoming message tree can cause the Resequence node to restore to its previous state, thus losing track of the state of group. A usertrace or service trace will show BIP2112E error, shown below, when such problem occurs: BIP2112E: Message broker internal error: diagnostic information ''failed to get message for event''
Problem conclusion
The Resequence node no longer fails to restore its previous state when an internal exception occurs. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.13 v11.0 11.0.0.1 v9.0 9.0.0.11 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT22578
Reported component name
INTEGRATION BUS
Reported component ID
5724J0530
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-10-12
Closed date
2018-06-12
Last modified date
2018-06-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0530
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
13 June 2018