Error description
When running an application activity trace of an application which handles an asynchronous MQ callback, such as the amqscbf sample, the activity trace reports an incorrect thread ID. The same error may be seen in the thread ID passed to an API exit for an asynchronous callback.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: Users of MQ V8 and later using application activity trace or API exits with applications using asynchronous callback routines. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: A logic error in the queue manager routines for recording application activity trace and invoking API exits meant that an incorrect thread ID was recorded when reporting asynchronous callback routine invocation.
Problem conclusion
The MQ product has been modified to set the correct thread id in API exits and application activity trace when used by asynchronous callback routines. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v8.0 8.0.0.9 v9.0 CD 9.0.5 v9.0 LTS 9.0.0.4 The latest available maintenance can be obtained from 'WebSphere MQ Recommended Fixes' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037 If the maintenance level is not yet available information on its planned availability can be found in 'WebSphere MQ Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT22390
Reported component name
WMQ BASE MULTIP
Reported component ID
5724H7251
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-09-13
Closed date
2018-02-13
Last modified date
2018-02-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WMQ BASE MULTIP
Fixed component ID
5724H7251
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
13 February 2018