Error description

  • When using using a TLS-enabled channel to perform AMS
    MCA interception, the following message is seen in the queue
    manager error logs:
    
    AMQ6174: The dynamically loadable shared library
    'lib64/libgsk8acmeidup_64.so' was not found. The system
    returned error number '2' and error message 'No such file or
    directory'
    
    No errors are reported to the application, and AMS processing
    takes place as expected despite the presence of this error.
    

Local fix

  • This error message can be ignored.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users who have configured AMS MCA interception on a SVRCONN
    channel which makes use of TLS or SSL.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    When using AMS MCA interception on a TLS-enabled channel,
    cryptographic libraries will be loaded in two stages. A subset
    of cryptographic libraries are loaded when the SVRCONN channel
    starts, and then additional libraries are required to be loaded
    when the first AMS-interceptable API call is made over the
    channel.
    
    The MQ library loading routines correctly detected this, and
    loaded the additional libraries when the first AMS-interceptable
    API call was made. However, a logic omission caused the AMQ6174
    message to be incorrectly reported during this load operation,
    even though the condition being reported was expected.
    

Problem conclusion

  • The AMS interceptor code has been corrected to suppress the
    AMQ6174 message for this expected condition when additional
    cryptographic libraries are being loaded.
    
    The AMQ6174 message will continue to be correctly reported in
    the event of an incorrectly configured system where the
    necessary cryptographic libraries are not present within the
    installation.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v9.0 CD    9.0.4
    v9.0 LTS   9.0.0.3
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT21298

  • Reported component name

    IBM MQ BASE M/P

  • Reported component ID

    5724H7261

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-07-05

  • Closed date

    2017-07-21

  • Last modified date

    2017-07-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IBM MQ BASE M/P

  • Fixed component ID

    5724H7261

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
21 July 2017