A fix is available
APAR status
Closed as program error.
Error description
Currently the option "updatectime", cannot be used with the dsmc command line (CLI) and the following error is returned: dsmc incr /proj/gpfs/test/ -updatectime=yes ANS1108E Invalid option (-UPDATECTIME) for the INCREMENTAL command Customer/L2 Diagnostics: The purpose of this APAR is to change the code so that "updatectime" is a valid command line option. Tivoli Storage Manager Versions Affected: IBM Spectrum Protect Backup-Archive clients versions 6.3 to 8.1.0 on AIX and Linux platforms Initial Impact: Low Additional Keywords: updatectime ANS1108E GPFS incremental
Local fix
Set the option in the client configuration file (dsm.opt) and retry the operation.
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Protect for Client versions 6.4, 7.1 and 8.1 * * running on Linux GPFS and AIX GPFS platforms * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION * **************************************************************** * RECOMMENDATION: * * Apply fixing level when available. This problem is projected * * to be fixed in level 8.1.2. Note that this is subject to * * change at the discretion of IBM. * **************************************************************** *
Problem conclusion
UPDATECTIME option will be available on incremental command line. The option documentation will be updated as follows: In the UNIX and Linux Backup-Archive Clients Installation and User's Guide, Chapter 10. Processing options > Client options reference > Updatectime The following text is updated: "Use the updatectime option to check the change time (ctime) attribute during an incremental backup operation." "Parameters no The backup-archive client does not check the change time (ctime attribute) during a backup operation. This value is the default. yes The backup-archive client checks the change time (ctime attribute) during a backup operation. If the ctime attribute changed since the last backup operation, the ctime attribute is updated on the IBM Spectrum Protect? server. The object is not backed up unless it has either ACLs or extended attributes. The client checks files and directories." The following text is removed: "Use this option with the incremental, selective, or archive commands."
Temporary fix
Comments
APAR Information
APAR number
IT18953
Reported component name
TSM CLIENT
Reported component ID
5698ISMCL
Reported release
71L
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-24
Closed date
2017-02-22
Last modified date
2017-02-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
dsmc
Fix information
Fixed component name
TSM CLIENT
Fixed component ID
5698ISMCL
Applicable component levels
R81L PSY
UP
R81A PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"71L","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
08 January 2022