Error description

  • FTP client can connect directly to IBM Sterling B2B
    Integrator and Sterling File Gateway in active mode successfully
    with the following command flow:
    
    FTP Commands given:
    LOGIN
    LS
    CWD
    PUT
    
    However, when the same connection is made through SSP the
    connection is rejected with the message:
    "451 Requested action aborted: session in inconsistent state".
    

Local fix

  • STRRTC - 510494
    PU/PU
    Circumvention:
    We have modified the code to accept the PWD command in that FTP
    state (internal state) which was earlier not designed to
    accept.
    state where PWD is defined as an accepted command. The fix
    right now provided is to allow PWD command in this new state.
    

Problem summary

  • Users Affected:
    All
    
    Problem Description:
    When the FTP client (windows or filezilla), in active mode,
    makes a connection through SSP, then the connection is
    rejected with the message: "451 Requested action aborted:
    session in inconsistent state".
    
    Platforms Affected:
    All
    

Problem conclusion

  • Resolution Summary:
    A code fix is provided.
    
    Delivered In:
    5020500_15
    5020601_7
    5020603_1
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT17614

  • Reported component name

    STR FILE GATEWA

  • Reported component ID

    5725D0700

  • Reported release

    225

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-10-24

  • Closed date

    2017-01-23

  • Last modified date

    2017-03-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR FILE GATEWA

  • Fixed component ID

    5725D0700

Applicable component levels

[{"Line of Business":{"code":"LOB02","label":"AI Applications"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS4TGX","label":"IBM Sterling File Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2"}]

Document Information

Modified date:
03 March 2021