APAR status
Closed as program error.
Error description
If bipservice process goes down for some reason, the user cannot stop the broker using 'mqsistop' or mqsistop -i' command.
Local fix
N/A
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus v9.0 on Unix and Linux platforms Platforms affected: AIX, HP-UX PA-RISC platform, HP-UX Itanium platform, Linux on Power platform, Linux on x86 platform, Linux on x86-64 platform, Linux on zSeries platform, Solaris x86-64 platform, Solaris SPARC platform **************************************************************** PROBLEM DESCRIPTION: It is not possible to stop n Integration node using either 'mqsistop' or 'mqsistop -i' if the bipservice process for the Integration Node is down, for example if it has been killed, or has crashed. There are a number of resource name changes between WebSphere Message Broker and IBM Integration Bus Version 9.0. For details visit http://pic.dhe.ibm.com/infocenter/wmbhelp/v9r0m0/topic/com.ibm.e tools.mft.doc/bb23814_.htm
Problem conclusion
Product has been modified so that it is now possible to stop the Integration Node using 'mqsistop -i' option even if the Integration Node's bipservice process is not running. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v9.0 9.0.0.9 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT16293
Reported component name
INTEGRATION BUS
Reported component ID
5724J0530
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-07-26
Closed date
2017-09-27
Last modified date
2017-09-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0530
Applicable component levels
R900 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0"}]
Document Information
Modified date:
10 September 2020