IBM Support

IT14476: [WINDOWS 10] TRAY ITEM ICON IS DUPLICATED IN SOME CONDITIONS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • [Update]
    
    Eclipse team has fixed the issue. Please get the code change
    from the following
    bugzilla link and merge it to XPD.
    
    [Problem]
    
    * The issue has been reported to Eclipse:
    https://bugs.eclipse.org/bugs/show_bug.cgi?id=488739. *
    
    The issue was reported by some IBM Sametime customers. They said
    the Sametime
    icon in system tray was duplicated many times. After checking
    the issue, I
    think it's a generic issue of SWT Tray component. I reported the
    bug as
    critical because our Sametime customer requests urgent fix from
    us.
    
    The customer is using Windows 10. They have told me the
    following cases that
    they see multiple icons:
    
    1. Close the lid and reopen it;
    2. Change the screen resolution or scale factor.
    
    I personally can't reproduce the issue with first approach. But
    I am able to
    regularly reproduce the bug by changing scale factor in Display
    setting. In
    Windows 10, you can set scale factor in "Settings" -> "Display"
    -> "Change the
    size of text, apps, and other items". Slide the bar to set a
    different scale
    factor which is greater than 100%. Do not log out. You will see
    an existing
    tray icon is duplicated by itself. Each time when you change to
    a new scale
    factor, a new copy of the icon will be created. These icons will
    not disappear
    if you hover the mouse upon them. They stay in the system tray
    till the
    application quits. But they are not operational at all,
    irresponsible to your
    click or right click.
    

Local fix

  • Restart Notes client
    

Problem summary

  • A programming error was found and will be corrected in a future
     release.
    

Problem conclusion

  • A programming error was found and will be corrected in a future
     release.
    

Temporary fix

Comments

  • This APAR is associated with SPR# LQIUA7W8EU.
    A programming error was found and will be corrected in a future
     release.
    

APAR Information

  • APAR number

    IT14476

  • Reported component name

    LOTUS EXPEDITOR

  • Reported component ID

    5724R0900

  • Reported release

    901

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-03-24

  • Closed date

    2016-09-14

  • Last modified date

    2016-09-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    LOTUS EXPEDITOR

  • Fixed component ID

    5724R0900

Applicable component levels

  • R901 PSN

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSVHEW","label":"Lotus Expeditor"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: