  • Closed as program error.

Error description

  • When sending files >30k bytes using Connect Direct Windows
    Secure+ (TLS 1.2) in binary mode to CDSA adapter as the
    SNODE, in the cdinterop_cdjava log in FM71 it posts error
    'encrypted mode; this buffer is fragmented (bytes read: 40
    bytes remaining: 16165 new offset: 40)' and
    java.lang.IndexOutOfBoundsException.
    If Secure+ is turned off, this session runs successfully.
    
    The software has been re-installed and we experience failures
    constantly with the job going into a loop.
    The servers is Windows 2012, with Connect Direct 4.7 iFix15 and
    secure +.
    
    The following errors appear on the Connect Direct Windows side
    in this order:
    LSMG622I
    LIPT011I
    LIPT016I
    LSMG616I
    SMGR failed to send a FMH74 to the remote Session
    LIPT016I
    A call to read_retry() failed to return anything.  The
    connection has been lost.
    

Local fix

  • STRRTC - 492631
    LRB / LRB
    Circumvention: None
    

Problem summary

  • Users Affected:
    All
    
    Problem Description:
    When sending files >30k using CD Windows Secure+ (TLS 1.2) in
    binary mode to CDSA as SNODE, the CDSA throws
    java.lang.IndexOutOfBoundsException.
    
    Platforms affected:
    All
    

Problem conclusion

  • Resolution Summary:
    A code fix has been provided.
    NOTE: This fix also removed the 16K buffer size resrtiction when
    Secure+ is configured.
    
    Delivered In:
    5020601_2
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT14024

  • Reported component name

    STR FILE GATEWA

  • Reported component ID

    5725D0700

  • Reported release

    226

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-02-29

  • Closed date

    2016-03-23

  • Last modified date

    2016-04-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR FILE GATEWA

  • Fixed component ID

    5725D0700

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS4TGX","label":"Sterling File Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
25 August 2023