  • A queue manager running from an MQ 8.0.0.4 installation has been
    started at Command Level 802.  For example, this command has
    been run: strmqm -eCMDLEVEL=802 QMNAME
    
    The problem is seen if the user uses the setmqm program to try
    to change the installation for that queue manager from 8.0.0.4
    to 8.0.0.3.
    
    The setmqm program fails with:
    AMQ5688: Unable to associate queue manager '<qmgr_name>' with
    installation '<Installation_name>'.
    
    This operation ought to be valid, because CommandLevel 802 is
    supported by both 8.0.0.3 and 8.0.0.4.
    
    The same problem is seen if the CommandLevel was changed to 802
    in both the following scenarios:
    1.Queue manager is changed to CommandLevel 802 while running
    8.0.0.3, then is changed to an 8.0.0.4 installation, then is
    changed back to an 8.0.0.3 installation.
    2.Queue manager is changed to CommandLevel 802 while running
    8.0.0.4, then is changed to an 8.0.0.3 installation.
    

Local fix

  • ONLY if CommandLevel=802 then the following workaround is valid.
    
    Change the text in qmstatus.ini from
      MinimumRequiredVersion=8.0.0.4
    to
      MinimumRequiredVersion=8.0.0.3
    and re-run the setmqm command.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Only users in the scenario described.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    The setmqm program reads text from the qmstatus.ini file to
    decide whether a the target installation is at a minimum level
    of MQ code required for the command level that the user has
    configured.
    
    The wrong text had been stored in the qmstatus.ini file during
    the running of strmqm -eCMDLEVEL=802 QMNAME
    
    The wrong text was: MinimumRequiredVersion=8.0.0.4
    

Problem conclusion

  • The IBM MQ product code has been corrected so that the correct
    text is stored in the qmstatus.ini file during the running of
    strmqm -eCMDLEVEL=802 QMNAME
    
    For CommandLevel=802 the correct text is:
    MinimumRequiredVersion=8.0.0.3
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v8.0       8.0.0.5
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT13017

  • Reported component name

    WMQ BASE MULTIP

  • Reported component ID

    5724H7251

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-01-05

  • Closed date

    2016-03-23

  • Last modified date

    2016-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WMQ BASE MULTIP

  • Fixed component ID

    5724H7251

Applicable component levels

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.0.0","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]