Error description
Troubleshooter > Business Process Usage confirmation screen will contain duplicates if [Check All] button is clicked several times When clicking the Troubleshooter -> [Check All] button an array is built of all the processes. If you click the [Check All] button again, it does not reinitialize the array, but rather the list of business processes are appended to the existing array. After clicking [Go] the confirmation screen will show duplicates in the business process list.
Local fix
STRRTC: 487424 CR/CR Circumvention: none
Problem summary
Users Affected: ALL Problem Description: When using Troubleshooter > Business Process Usage to restart business processes the processes will be restarted multiple times if you click [Check All] several times Platforms Affected: All
Problem conclusion
The problem was in the code where it was adding the Collection object. We need to clear this object everytime we do add all to this collection object. DELIVERED IN : 5020601_2
Temporary fix
Comments
APAR Information
APAR number
IT12857
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
525
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-12-18
Closed date
2016-04-14
Last modified date
2016-04-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
R526 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.5","Edition":"","Line of Business":{"code":"LOB02","label":"AI Applications"}}]
Document Information
Modified date:
18 April 2016