Error description
FTP Client PUT service changes a lone 0x0d to a 0x0a when a file is transferred in ASCII mode. This is a problem when an EDI file uses a 0x0D as the segment terminator at the receipient's insistence and the recipient lacks the capacity to receive the file in binary mode or accept a 0x0A as the terminator.
Local fix
No workaround
Problem summary
Users Affected: All Problem Description: FTP Client PUT service changes a lone 0x0d to a 0x0a when a file is transferred in ASCII mode. Platforms Affected: Windows UNIX Linux
Problem conclusion
Resolution Summary: A code fix has been provided. A new property has also been added for backward compatibilty. When this property is set to true Sterling B2B Integrator will not convert the lone 0D(CR) character to 0D0A(CRLF). The new property ignoreLoneCRinASCIImode has been added to psftpclient.properties. Delivered In: 5020500_9
Temporary fix
Comments
APAR Information
APAR number
IT10841
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
525
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-08-21
Closed date
2015-09-11
Last modified date
2015-09-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
R525 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.5","Edition":"","Line of Business":{"code":"LOB02","label":"AI Applications"}}]