APAR status
Closed as program error.
Error description
An abend occurs when using an Aggregation Reply Node that has been configured to use multiple time out threads via a configurable service when statistics are turned on. The actual abend can occur in the timeout thread or the collector thread which publishes the statistics. Additional Symptom(s) Search Keyword(s): Aggregation Reply Node, Statistics, Abend, timeout thread
Local fix
<html>None </html>
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus and Aggregation nodes when using multiple timeout threads with statistics turned on. Platforms affected: z/OS, MultiPlatform **************************************************************** PROBLEM DESCRIPTION: A flow has an aggregation reply node which has been configured to use multiple time out threads. When turning on accounting and statistics for that flow, the broker can abend . <i>There are a number of resource name changes between WebSphere Message Broker and IBM Integration Bus Version 9.0. For details visit http://pic.dhe.ibm.com/infocenter/wmbhelp/v9r0m0/topic/com.ibm.e tools.mft.doc/bb23814_.htm</i>
Problem conclusion
The product has been updated to stop the statistics from causing an abend with the Aggregation Reply node. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.4 v8.0 8.0.0.9 v9.0 9.0.0.6 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT09822
Reported component name
INTEGRATION BUS
Reported component ID
5724J0530
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-07-02
Closed date
2016-03-07
Last modified date
2017-03-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0530
Applicable component levels
R900 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
23 March 2020