APAR status
Closed as program error.
Error description
Probes to Storage device fail to persist new data due to DB2 SQL Error: SQLCODE=-811, SQLSTATE=21000 dmvSvcTrace.log 2015-06-17 11:59:39.466-0300 HWN099992W SQL Exception while persisting properties: {member_id=x, physicalvolumeid=xxxx, device_id=x, rpm=, mdisk_id=xx, ref_napi_id=xxx, uid=xxxxxxxxxxxxxx, is_solid_state=1, vendor_id=xxxx, ref_serviceurl=, node_name=, consolidated_status=0, tech_type=sas_ssd, operational_status=4, mdisk_name=mdisk21, firmware_rev=GB6Y, name=5, discovered_time=2015-06-17 11:59:39.462, node_id=, enclosure_id=xx, fru_identity=xxxxxxxxxxxxxxxxxxxxxxx, product_id=xxxxxxxxxxxxxxxxxxxxxxxx, port_1_status=online, disk_type=4, flags=0, ref_namespace=, fpga_level=, update_timestamp=2015-06-17 11:59:39.464, port_2_status=online, firmware_level=GB6Y, device_type=DSRA_SVC, capacity=xxxxxxxxxxxxx, status=1, serial_number=xxxxxxxxxxxxxxxxxxxxxxxxxxx, ref_classname=ldisk, detectable=1, fru_part_number=85Y6189, id=5, block_size=512, physical_volume_id=9641719, display_name=5, job_logger=com.ibm.tpc.disk.common.log.LogTraceHelper@2938fdd1, storageextentid=xxxxxxxxxxxxxx, model_id=xxxx, subsystem_id=xxxx, tag=20, quorum_id=, section name=ldisk, use=member, svc_key_metadata=1, start_time=Wed Jun 17 11:59:07 BRT 2015, slot_id=19, ref_system_names_id=1004, error_sequence_number=}@(-9223372036837974743;[-9223372036836765 612,0,4];-9223372036836765353;Process Processor (Thread-416051)) com.ibm.tpc.disk.collection.DiskCIMProcessor persist 2015-06-17 11:59:39.467-0300 HWN099993E DB2 SQL Error: SQLCODE=-811, SQLSTATE=21000, SQLERRMC=null, DRIVER=3.62.56 @(-9223372036837974743;[-9223372036836765612,0,4];-9223372036836 765353;Process Processor (Thread-416051)) com.ibm.db2.jcc.am.SqlException: DB2 SQL Error: SQLCODE=-811, SQLSTATE=21000, SQLERRMC=null, DRIVER=3.62.56 at com.ibm.db2.jcc.am.fd.a(fd.java:679) at com.ibm.db2.jcc.am.fd.a(fd.java:60) at com.ibm.db2.jcc.am.fd.a(fd.java:127) at com.ibm.db2.jcc.am.jn.b(jn.java:2299) at com.ibm.db2.jcc.am.jn.c(jn.java:2282) at com.ibm.db2.jcc.t4.cb.k(cb.java:370) at com.ibm.db2.jcc.t4.cb.a(cb.java:62) at com.ibm.db2.jcc.t4.q.a(q.java:50) at com.ibm.db2.jcc.t4.sb.b(sb.java:220) at com.ibm.db2.jcc.am.kn.lc(kn.java:3077) at com.ibm.db2.jcc.am.kn.b(kn.java:4034) at com.ibm.db2.jcc.am.kn.dc(kn.java:746) at com.ibm.db2.jcc.am.kn.executeUpdate(kn.java:729) at com.ibm.tpc.infrastructure.database.DBPreparedStatement.executeU pdate(DBPreparedStatement.java:261) at com.ibm.tpc.infrastructure.mapping.CLISVC6_LDiskToPhysicalVolume DBMapper.persistDiskGroupIDForLDisk(CLISVC6_LDiskToPhysicalVolum eDBMapper.java:330) at com.ibm.tpc.infrastructure.mapping.CLISVC6_LDiskToPhysicalVolume DBMapper.persist(CLISVC6_LDiskToPhysicalVolumeDBMapper.java:272) at com.ibm.tpc.disk.collection.DiskCIMProcessor.persist(DiskCIMProc essor.java:1868) at com.ibm.tpc.discovery.parser.NAPI_DS_SVC_Parser.persistEntity(NA PI_DS_SVC_Parser.java:295) at com.ibm.tpc.discovery.parser.NAPI_DS_SVC_Parser.processOutputFil e(NAPI_DS_SVC_Parser.java:223) at com.ibm.tpc.disk.discovery.SVC_CLI_PostProcess.parse(SVC_CLI_Pos tProcess.java:87) at com.ibm.tpc.disk.discovery.NAPIProbePostProcess.process(NAPIProb ePostProcess.java:384) at com.ibm.tpc.Router.perform(Router.java:1077) at com.ibm.tpc.Router.perform(Router.java:599) at com.ibm.tpc.discovery.ProcessProcessor.process(ProcessProcessor. java:69) at com.ibm.tpc.infrastructure.threads.TPCThread.run(TPCThread.java: 258)com.ibm.tpc.disk.collection.DiskCIMProcessor persist RECREATE STEPS: Probe Device and view reports after name changes to device data. Problem as described by customer: Renamed v7k vdisks do not display correct name in TPC WEB GUI Initial customer impact: Med
Local fix
Contact Support
Problem summary
**************************************************************** * USERS AFFECTED: * * TPC 5.2.x running storage probes * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION for DB2 SQL error. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0007 - target August 2015 http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT09779
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-07-02
Closed date
2015-07-20
Last modified date
2015-07-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PROBE
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R520 PSY
UP
R526 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
22 February 2022