IT09307: IT'S NOT POSSIBLE TO SPECIFY MULTIPLE HOST KEYS DIRECTLY IN THE SFTP CLIENT ADAPTER BEGIN SESSION SERVICE.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • 5.2.5_4
    
    Even though multiple host keys can be used with SFTP when using
    remote profiles, it is not possible to specify multiple host
    keys directly in the BP using the SFTP Client Begin
    Session service
    

Local fix

  • STRRTC - 467898
    PdO / PdO
    Circumvention: Use remote profiles
    

Problem summary

  • USERS AFFECTED:
    ALL
    
    PROBLEM DESCRIPTION:
    USE MULTIPLE KNOWN HOST KEYS IN SFTP CLIENT BEGIN SESSION
    
    PLATFORMS AFFECTED :
    ALL
    

Problem conclusion

  • RESOLUTION SUMMARY:
    WHEN SUPPORT FOR MULTIPLE KNOWN HOST KEY(KHK) WAS INTRODUCED IN
    SI, THERE WAS A MISSING CODE TO HANDLE THE MULTIPLE KHK
    SPECIFIED VIA THE SFTP BEGIN SESSION SERVICE. THE SAME WORKS
    JUST FINE WHEN SPECIFIED USING THE SSH PROFILE.
    CORRECTED THIS ERRONEOUS BEHAVIOR SO THAT SI TAKES INTO ACCOUNT
    THE MULTIPLE KHK SEPARATED USING COMMA IN THE BP ITSELF. WITH
    THIS NEW CHANGE,THE SFTP SESSION USING THE PUBLIC KEY
    AUTHENTICATION WHEN MULTIPLE KHK IS SPECIFIED IN THE BP,IS
    SUCCESSFUL TO THE INTENDED SFTP SERVER.
    
    DELIVERED IN:
    5020500_6
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT09307

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    525

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-06-05

  • Closed date

    2015-06-10

  • Last modified date

    2015-06-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

  • R525 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.5","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
19 June 2015