IBM Support

IT09206: INCORRECT INPUT FILE CAUSES EDIFACT DEENVELOPE SERVICE TO GET STUCK IN ACTIVE STATE, WHICH CRASHES STERLING B2B INTEGRATOR

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • EDIFACT Deenvelope Service can't handle incorrect input file
    and gets stuck in Active state, causing OOM and  Sterling B2B
    Integrator to
    crash. Looks like the EDIFACT Deenvelope service was unable to
    handle the incorrect input file (irregular EDI file that
    has UNH between UNT and UNZ).
    If you run more than one instance of EDIDeenvelope BP, those BPs
    will stay in 'Active" state and exhaust the free memory,
    which at some point leads to the system hanging, an OOM
    error and crash.
    

Local fix

  • STRRTC# 467092
    JX/JX
    Circumvention: None
    

Problem summary

  • Users Affected:
    Customers who use standards enveloping
    
    Problem Description:
    EDIFACT Deenvelope Service can't handle incorrect input file
    and gets stuck in Active state, finally causing the system to
    hang, an OOM error, and system crash.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Resolution Summary:
    A code fix has been provided.
    
    Delivered In:
    5020500_9
    5020600
    5105
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT09206

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    524

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-06-01

  • Closed date

    2015-06-03

  • Last modified date

    2016-04-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    TRANSLAT
    ENVELOPE
    

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.4","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date: