APAR status
Closed as program error.
Error description
When performing a basic or advanced search in Sterling File Gateway, the default sort order that should be "Discovery Time" is no longer set. It must be set manually.
Local fix
STRRTC - 458053 PdO / PdO Circumvention: None
Problem summary
USERS AFFECTED: Sterling File Gateway users PROBLEM DESCRIPTION: Sterling File Gateway ACTIVITY SEARCH RESULTS DEFAULT SORT ORDER NO LONGER SET. PLATFORMS AFFECTED: ALL
Problem conclusion
RESOLUTION SUMMARY: A code fix has been provided so that the default sort order on the discovery time in the Arrived File Search UI is set. DELIVERED IN: 5020500_5
Temporary fix
Comments
APAR Information
APAR number
IT08735
Reported component name
STR FILE GATEWA
Reported component ID
5725D0700
Reported release
225
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-05-06
Closed date
2015-05-14
Last modified date
2015-05-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR FILE GATEWA
Fixed component ID
5725D0700
Applicable component levels
R225 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS4TGX","label":"IBM Sterling File Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2","Edition":"","Line of Business":{"code":"LOB02","label":"AI Applications"}}]
Document Information
Modified date:
26 May 2015