Error description

  • The Healt Check Tool does not provide some recommendations
    on Oracle memory parameters.
    

Local fix

  • STRRTC - 452282
    JPM
    

Problem summary

  • Problem Description:
    The SGA_TARGET and PGA_AGGREGATE_TARGET tests were using Oracle
    10g recommended values even if the customer was on a later
    version of Oracle.  In Oracle 11g, new parameters were
    introduced for configuring memory management and the recommended
    values for existing parameters (for example, SGA_TARGET
    and PGA_AGGREGATE_TARGET) changed.
    

Problem conclusion

  • Resolution Summary:
    New properties have been added and two new tests for the new
    parameters
    MEMORY_TARGET and MEMORY_MAX_TARGET.  The Oracle scanner
    now checks the database version and runs the appropriate tests
    with the correct recommended values for SGA_TARGET and
    PGA_AGGREGATE_TARGET.
    
    This fix is available in Health Check Tool V1.0.2.1, which is
    available with Sterling B2B Integrator V5.2.5, Interim Fix 4.
    
    Delivered In:
    5020500_4
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT08205

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-04-09

  • Closed date

    2015-04-20

  • Last modified date

    2015-04-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

  • R525 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"LOB02","label":"AI Applications"}}]

Document Information

Modified date:
28 April 2015