APAR status
Closed as program error.
Error description
If HealthCheck 1.0.1 is installed in Sterling B2B Integrator, the patch 5.2.5 will fail if the operating system is SunOS.
Local fix
Circumvention: Remove HealthCheck parameters from sandbox.cfg ({$clump.var.prefix}) and re-run the patch.
Problem summary
Problem Description: Customers who have installed the beta version of the HealthCheck tool (version 1.0.1) may experience difficulty or even failure when upgrading Sterling B2B Integrator V5.2.5. The upgrade includes an automatic installation of HealthCheck 1.0.2. Platforms Affected: Solaris Users Affected: Customers who installed the beta version of the HealthCheck tool (version 1.0.1).
Problem conclusion
Resolution Summary: A method was added to perform a post-installation cleanup of all malformed HealthCheck 1.0.1 property names and directories. Delivered In: 5020500_3
Temporary fix
Manually remove the 3 malformed properties from sandbox.cfg. 1) ${clump.var.prefix}_BUILD_NUMBER 2) ${clump.var.prefix}_PRODUCT_LABEL 3) ${clump.var.prefix}_LIC_PROD_VERSION
Comments
APAR Information
APAR number
IT07728
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
525
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-03-16
Closed date
2015-03-17
Last modified date
2015-03-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
R525 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.5","Edition":"","Line of Business":{"code":"LOB02","label":"AI Applications"}}]
Document Information
Modified date:
24 March 2015