Error description

  • Inbound node was not in the Secure+ netmap, so an error was
    issued; CSPA081E-Unable to initialize workspace.
    
    SPADMIN has *LCLNODE Secure+=N and Override=Y, so there
    should only have been a warning not a fatal error.
    

Local fix

  • STRRTC - 458011
    SF / SF
    Circumvention: None
    

Problem summary

  • Users Affected:
    Customer installing C:D i5/OS who did not populate SPADMIN with
    the correct remote node names
    Problem Description:
    Hard failure occurs instead of a warning message that the
    remote entry is not found in SPADMIN.
    Platforms Affected:
    All
    

Problem conclusion

  • Resolution Summary:
    Put in warning message if the PNODE did not ask for Secure+,
    and the LOCAL entry is create with Secure+=N Override=Y in the
    SNODE.
    Delivered In:
    1503A
    

Temporary fix

  • Add the remote user to SPADMIN in the correct case coming from
    the remote.
    

Comments

APAR Information

  • APAR number

    IT07472

  • Reported component name

    STR CD FOR I5/O

  • Reported component ID

    5725C9905

  • Reported release

    380

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-03-03

  • Closed date

    2015-03-04

  • Last modified date

    2015-03-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • smmain.c
    

Fix information

  • Fixed component name

    STR CD FOR I5/O

  • Fixed component ID

    5725C9905

Applicable component levels

  • R380 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSRS27","label":"IBM Sterling Connect:Direct for i5\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"380","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
04 March 2015