APAR status
Closed as program error.
Error description
Audit log displaying error 6-1-50003 and the Gentran services seem to be running fine. Unsettling to think there could be infrastructure issues with connecting to RPC.
Local fix
STRRTC 455655 MAH/MAH
Problem summary
User Affected: Customer experiencing communication problems with gencom97 Problem Description: Audit Log error, 6-1-50003 RpcServerUseProtseqEp (Local) failed at line 300: The endpoint is a duplicate, reported when gencom97 fails.
Problem conclusion
Resolution Summary: Verified that error occurs if additional instances of gencom97 are started when it is already running. Added additional information to audit message, RpcServerUseProtseqEp (Local) failed at line 437: The endpoint is a duplicate. Another instance of the program may already be running.
Temporary fix
Comments
APAR Information
APAR number
IT07196
Reported component name
STR GENTRAN MS
Reported component ID
5725D0903
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-02-17
Closed date
2015-09-30
Last modified date
2015-09-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR GENTRAN MS
Fixed component ID
5725D0903
Applicable component levels
R530 PSY
UP
R531 PSY
UP
[{"Business Unit":{"code":"BU055","label":"Cognitive Applications"},"Product":{"code":"SS6V3G","label":"Sterling Gentran:Server for Microsoft Windows"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: