APAR status
Closed as program error.
Error description
If $ONCONFIG TAPEDEV is defined with Windows Long File Name format, with spaces in between the paths, archecker will fail to read the archive. in $ONCONFIG TAPEDEV C:\Program Files\IBM Informix Software Bundle\tapedev When running archecker, it would show AC_TAPEDEV as "C:\PROGRAM" only and failed to get the full path. ============================== C:\Program Files\IBM Informix Software Bundle\tapedev>archecker -tvds IBM Informix Dynamic Server Version 12.10.FC4W1WE Program Name: archecker Version: 8.0 Released: 2014-09-09 21:40:25 CSDK: IBM Informix CSDK Version 4.10 ESQL: IBM Informix-ESQL Version 4.10.FC5 Compiled: 09/09/14 21:41 on Windows_NT 5 02 AC_STORAGE c:\temp AC_MSGPATH c:\temp\ac_msg.log AC_VERBOSE on AC_TAPEDEV "C:\PROGRAM AC_TAPEBLOCK 16 KB AC_LTAPEDEV nul AC_LTAPEBLOCK 16 KB AC_TIMEOUT 300 AC_SESSION Please put in Phys Tape 1. Type <return> or 0 to end: CreateFile(): w32ec=123 at nt_filio.c:353 Error(0) opening tape device("C:\PROGRAM) Scan FAILED ============================== Workaround is to modify TAPEDEV to Short format without spaces TAPEDEV C:\PROGRA~1\IBMINF~1\Storage\tapedev
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IDS-12.10.xC5 * ****************************************************************
Problem conclusion
Problem Fixed In IDS-12.10.xC5
Temporary fix
Comments
APAR Information
APAR number
IT05518
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-11-11
Closed date
2015-10-16
Last modified date
2015-10-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
RC10 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: