IBM Support

IT04886: X12DEENVELOPEUNIFIED BP SCENARIO - THE BOOTSTRAPPED BP RECEIVES THE CORRECT REFERENCE NUMBER AND ALSO OF THE FAILED DOCUMENT.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The inbound X12
    interchange contains 5 transaction sets. Each transaction set
    is to be deenveloped and translated into separate XML
    documents. Each transaction set contains a
    reference number that is
    identified by the map and placed into ProcessData for use in
    the bootstrapped post-processor BP.
    
    The X12DeenvelopeUnified BP should therefore have 5 child
    BPs, each with a different reference number in its ProcessData.
    But one of the transaction sets is missing
    some data and fails the compliance check.  The post-processor BP
    that gets bootstrapped for the failed document does not contain
    the document's reference number in its ProcessData.
    
    The problem is that the bootstrapped post-processor BP for one
    of the good documents receives both the correct reference number
    and that of the failed document.
    

Local fix

  • STRRTC - 429209
    LB / RB
    Circumvention: None
    

Problem summary

  • Problem Description:
    The bootstrapped post-processor BP
    receives both the correct reference number and that of
    the failed document.
    
    Platforms Affected:
    All
    
    Users Affected:
    All
    

Problem conclusion

  • Resolution Summary:
    Fixed process data updates for compliance check operations that
    produce only output errors.
    
    Delivered In:
    5020500_3
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT04886

  • Reported component name

    STR B2B INTEGRA

  • Reported component ID

    5725D0600

  • Reported release

    523

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-10-13

  • Closed date

    2015-03-05

  • Last modified date

    2015-03-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR B2B INTEGRA

  • Fixed component ID

    5725D0600

Applicable component levels

  • R525 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.3","Edition":"","Line of Business":{"code":"LOB02","label":"AI Applications"}}]

Document Information

Modified date: