Error description

  • When using a local Managed File Transfer (MFT) configuration,
    the WebSphere MQ v8.0 Explorer fails to connect the MFT
    configuration to the defined coordination and command queue
    managers. The WebSphere MQ v8.0 Explorer does not display any
    error or warning messages.
    
    When WebSphere MQ v8.0 Explorer tracing is enabled, an FFDC file
    is generated with the following information when the user
    attempts to connect the MFT configuration:
    
    Level: f800-20140813-1141
    Time: 24/10/2014 10:39:51:159 EDT
    Thread: 1 (main)
    Class: com.ibm.wmqfte.configuration.FTEPropertiesFactory
    Method: getInstance
    Probe: FFDC_002
    Cause: com.ibm.wmqfte.configuration.FTEConfigurationException:
    BFGUB0010E: Internal error: The configuration has not been
    initialized before first use.
    com.ibm.wmqfte.configuration.FTEConfigurationException:
    BFGUB0010E: Internal error: The configuration has not been
    initialized before first use.
    at
    com.ibm.wmqfte.configuration.FTEPropertiesFactory.getInstance(FT
    EPropertiesFactory.java:175)
    at
    com.ibm.wmqfte.userexits.impl.UserExitsFactoryImpl.(UserExitsFac
    toryImpl.java:198)
    at
    com.ibm.wmqfte.userexits.UserExitsFactory.initialise(UserExitsFa
    ctory.java:107)
    at
    com.ibm.wmqfte.explorer.data.Subscription.updateProperties(Subsc
    ription.java:345)
    at
    com.ibm.wmqfte.explorer.treenode.CoordTreeNode.connect(CoordTree
    Node.java:264)
    at
    com.ibm.wmqfte.explorer.treenode.CoordTreeNode.connect(CoordTree
    Node.java:249)
    at
    com.ibm.wmqfte.explorer.treenode.CoordTreeNode$3.run(CoordTreeNo
    de.java:162)
    
    
    In addition, the WebSphere MQ v8.0 Explorer trace file contains
    the entry:
    
    Exception thrown
    com.ibm.wmqfte.configuration.FTEConfigurationException:
    BFGUB0010E: Internal error: The configuration has not been
    initialized before first use.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    This issue affects all users of the WebSphere MQ Explorer
    version 8 Managed File Transfer (MFT) plug-in who create local
    MFT configurations.
    
    
    Platforms affected:
    Linux on x86, Linux on x86-64, Windows
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    Within the WebSphere MQ Explorer Managed File Transfer (MFT)
    plug-in, there are two types of MFT configuration. They are:
    
      - "global" configurations
    
      - "local" configurations.
    
    A global configuration is used when WebSphere MQ MFT has been
    installed alongside the WebSphere MQ Explorer, such that the
    WebSphere MQ Explorer MFT plug-in can access the MFT properties
    files.
    
    Whereas a local configuration is created when a user
    right-clicks on the "Managed File Transfer" folder within the MQ
    Explorer - Navigator pane, selects "New configuration..." and
    uses the resulting wizard to specify details such as the
    coordination and command queue managers to access their
    WebSphere MQ MFT topology.
    
    When a user attempted to "connect" a local WebSphere MQ Managed
    File Transfer (MFT) configuration within the WebSphere MQ
    Explorer, the MFT plug-in attempted to use a data structure, for
    accessing properties, that had not been initialised. This was
    because, with a local configuration, there are no on-disk
    property files to read and parse that would have resulted in
    this data structure being initialised.
    
    This resulted in an internal error being thrown, which in turn
    prevented the MFT plug-in from connecting to the WebSphere MQ
    coordination queue manager for the MFT topology to which the
    local configuration related. The internal error was caught
    within the WebSphere MQ Explorer however and no error message
    was displayed to the user.
    

Problem conclusion

  • The WebSphere MQ Explorer Managed File Transfer (MFT) plug-in
    code has been updated such that the data structure for accessing
    properties is initialised with default values before being
    accessed when connecting to the WebSphere MQ coordination queue
    manager for the MFT topology.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v8.0       8.0.0.2
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT04759

  • Reported component name

    WMQ BASE MULTIP

  • Reported component ID

    5724H7251

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-10-06

  • Closed date

    2014-10-30

  • Last modified date

    2014-10-30

  • APAR is sysrouted FROM one or more of the following:

    XX00219

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WMQ BASE MULTIP

  • Fixed component ID

    5724H7251

Applicable component levels

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
30 October 2014