A fix is available
APAR status
Closed as program error.
Error description
Collecting the System logs from the System Console > Troubleshooting page on PureApplication System fails to complete. The error seen is: CWZIP3322W Tivoli System Automation diagnostic data cannot be collected The PureSystems Managers command utility: psm collect may also fail to execute due to the same error.
Local fix
Problem summary
Tivoli System Automation logs were not being gathered in the system collection set because a script file to gather the logs was timing out.
Problem conclusion
An updated collection script file is being provided to fix the issue.
Temporary fix
Comments
APAR Information
APAR number
IT04712
Reported component name
PAPP SYS 8382 I
Reported component ID
5725G3200
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-10-02
Closed date
2014-11-12
Last modified date
2014-11-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
PAPP SYS 8382 I
Fixed component ID
5725G3200
Applicable component levels
R110 PSY
UP
R200 PSY
UP
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSM8NY","label":"PureApplication System"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0.0"}]
Document Information
Modified date: