A fix is available
APAR status
Closed as program error.
Error description
A full VM Instant restore/access operation will time out if more than one iSCSI adapter is present on the ESXi host. In the dsmerror.log of the datamover node the following will be seen : FBSC1413I Working with Recovery Agent on 1.2.3.4 (1.2.3.4) FBSC1428I Waiting for connection to Recovery Agent 1 seconds... ... ANS2435E TDP for VMware Recovery Agent detected the following failure while trying to mount a snapshot of VM 'vmname' from disc='Hard Disk 1': FBSC6426E Connection timeout to Recovery Agent after 30 seconds... ANS2411E Instant Restore/Access of virtual machine 'vmname' failed with rc = 6541 ANS4907E Instant restore of VMware Virtual Machine 'vmname' failed. target node name='DATACENTER', data mover node name='DATAMOVER' Tivoli Storage Manager Versions Affected: Tivoli Storage Manager for Virtual Environment - Data Protection for VMware on Windows and Linux 7.1 Customer/L2 Diagnostics (If Applicable) Initial Impact: Medium Additional Keywords: zz71 VMware recovery agent 6541 iSCSI IA IR restore
Local fix
Ensure that there is only one iSCSI adapter on the ESXi host
Problem summary
**************************************************************** * USERS AFFECTED: Tivoli Storage Manager for Virtual * * Environments version 7.1 running on all * * Windows platforms * **************************************************************** * PROBLEM DESCRIPTION: see ERROR DESCRIPTION * **************************************************************** * RECOMMENDATION: This issue is projected to be fixed in the * * Tivoli Storage Manager Client on Windows 7.1.1* * Note 1: The Tivoli Storage Manager (TSM) * * Client is a prerequisite to using the Data * * Protection for VMware. In Data Protection for * * VMware environments, the TSM Client is also * * known as the data mover. * * Note 2: This is subject to change at the * * discretion of IBM. * ****************************************************************
Problem conclusion
The TSM client will now correctly identify the first available iSCSI adapter on the ESXi host or correctly honor the newly documented VMISCSIADAPTER option to select a specific adapter when more than one is present.
Temporary fix
Comments
APAR Information
APAR number
IT01699
Reported component name
TSM FOR VE DP V
Reported component ID
5725TVEVM
Reported release
71W
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-13
Closed date
2015-03-12
Last modified date
2015-03-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TSM CLIENT
Fixed component ID
5698ISMCL
Applicable component levels
R71W PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"71W","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
12 March 2015