Error description
GIM65802E ** MODULE TSTSRC1 IS NEEDED TO BUILD THE FOLLOWING LOAD MODULES when APPLYing Usermod where the SRC is shipped in a prior usermod.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of SMP/E that APPLY USERMODs. * ****************************************************************
Problem conclusion
Consider a USERMOD that is applied and contains a ++SRC MOD1 but the source is not assembled and linked into any load modules. Consider a second USERMOD that contains JCLIN to define a load module that includes the assembled source MOD1 which was previously applied. When the second USERMOD is applied, SMP/E does not assemble the source MOD1 and instead issues an error message: GIM65802E ** MODULE MOD1 IS NEEDED TO BUILD THE FOLLOWING LOAD MODULES FOR SYSMOD usermod2 BUT IS NOT FOUND. THE MODULE IS NOT IN DISTRIBUTION ZONE dlibzonename, AND SYSMOD usermod1 WHICH LAST REPLACED THE MODULE IS NOT IN THE SMPPTS. This processing and error message will not be updated.
Temporary fix
Comments
APAR Information
APAR number
IO29126
Reported component name
SMP/E
Reported component ID
566894901
Reported release
K00
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-01-30
Closed date
2025-06-23
Last modified date
2025-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"K00"}]
Document Information
Modified date:
24 June 2025