APAR status
Closed as program error.
Error description
Store 54 (745 pilot store) reported that they found the touch screen hung on a 745 terminal. Terminal 92 had the #1 box on the keypad on the touch screen highlighted and the cursor there and the touch screen was unresponsive. I dumped the terminal and two dumps were listed as received (one on each controller) so I sent them both in.
Local fix
Problem summary
Operator perceives the touch as unresponsive. This condition manifest when at the console driver level a secondary display mutex is grabbed but never released, which is caused by a flag bit that is accidentally cleared by the mouse ISR.
Problem conclusion
The mouse ISR should respect the flag bits set the by the console mouse ASR, and that it relies on for the appropriate handling of events. It should only set those flag bits that it needs and leave the others unchanged.
Temporary fix
Comments
APAR Information
APAR number
IO17058
Reported component name
IBM 4690 OS V6
Reported component ID
5639P7000
Reported release
301
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-09-04
Closed date
2012-09-10
Last modified date
2013-07-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
VX_CSOMM
Fix information
Fixed component name
IBM 4690 OS V6
Fixed component ID
5639P7000
Applicable component levels
R301 PSY UO01437
UP13/07/30 P 0CD0
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SOULYT","label":"Point of Sale Software->4690 Operating System"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"301","Edition":"","Line of Business":{"code":"","label":""}}]