IBM Support

IJ58402: NMON SHOWS INCORRECT FCSUPPSPEED FOR 16,32,64,100 GB ADAPTERS

 

APAR status

  • Closed as program error.

Error description

  • Problem statement:
    -----------------
    nmon reording file shows incorrect FC supported speed
    (FCSUPPSPEED) for
    16,32,64,100Gbit FC adapters.
    
    Problem details:
    ----------------
    In VIOS, when part tool is run, the generated nmon
    recording
    file wrongly displays FC adapters supported speed for
    16,32,64 and 100 Gbit adapeters.
    
    Example: When fc supported speed is 16 Gbit, nmon shows
    value '0'
    
    # grep FCSUPP l3lpar24_260226_0315.nmon
    FCSUPPSPEED,Fibre Channel Supported Speed,fcs2,fcs3
    FCSUPPSPEED,T0001,0,0
    FCSUPPSPEED,T0002,0,0
    
    Whereas fcstat shows correct value
    
    # fcstat fcs3 | grep Speed
    Port Speed (supported): 16 GBIT   --> This Metric
    Port Speed (running):   8 GBIT
    
    (0) root @ l3lpar24: /home/padmin
    # fcstat fcs2 | grep Speed
    Port Speed (supported): 16 GBIT   --> This metric
    Port Speed (running):   16 GBIT
    

Local fix

Problem summary

  • When powervm health advisory metrics option is enabled for
    nmon, the collected nmon recording file shows wrong FC port
    Supported Speed (value 0) for FC adapter of 16Gbit or
    higher speeds.
    
    This is evident when part tool is used in VIOS to collect
    Performance adviosry reports.
    

Problem conclusion

  • modified code to support for 16,32,64,100Gbit FC adapters speed
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ58402

  • Reported component name

    AIX V7.3

  • Reported component ID

    5765CD300

  • Reported release

    730

  • Status

    CLOSED PER

  • HIPER

    NoHIPER

  • Submitted date

    2026-05-18

  • Closed date

    2026-05-18

  • Last modified date

    2026-05-18

  • APAR is sysrouted FROM one or more of the following:

    IJ57454

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.3

  • Fixed component ID

    5765CD300

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
18 May 2026